Kabel OLFLEX CLASSIC 110 5G1.5

Kategori: Control Cables | 1419 Kali Dilihat
Kabel OLFLEX CLASSIC 110 5G1.5 Reviewed by owner on . This Is Article About Kabel OLFLEX CLASSIC 110 5G1.5

CONTROL CABLE PVC outer sheath and numbered cores   Deskripsi Produk :  OLFLEX CLASSIC 110 Ukuran / Size :  5G 1.5 MM2 Voltage :  300/500 V         ■ Application range ▯ For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load… Selengkapnya »

Rating: 1.0
Harga:Rp 16.897
Order via SMS

+6281294396399

Format SMS : ORDER#NAMA PRODUK#JUMLAH
Pemesanan Juga dapat melalui :
SKU : 041
Stok Tersedia
12.8 Kg
14-03-2019
Detail Produk "Kabel OLFLEX CLASSIC 110 5G1.5"

CONTROL CABLE

PVC outer sheath and numbered cores

 

Deskripsi Produk :  OLFLEX CLASSIC 110

Ukuran / Size :  5G 1.5 MM2

Voltage :  300/500 V

 

 

 

 

Application range

▯ For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load

▯ Dry or damp rooms that are subject to medium mechanical loads

▯ Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)

▯ In power chains for a travelling distance up to 5 m and 0,2 … 1 million bending cycles, for following dimensions: 0,5 to 2.5mm² and 2 to 7 conductors

 

Product features

▯ Flame-retardant according IEC 60332-1-2

▯ Good chemical resistance, see catalogue appendix T1

▯ Oil-resistant according to DIN EN 50290-2-22 (TM54)

 

Norm references / Approvals

▯ VDE reg. no. 7030 for the following sizes: up to 2.5 mm²: 2 – 65 cores from 4 mm²: 2 – 7 cores

 

Product make-up

▯ Fine-wire strand made of bare copper wires

▯ PVC insulation LAPP P8/1

▯ Cores twisted in layers

▯ PVC outer sheath, grey (RAL 7001)

 

Technical data

Classification

ETIM 5.0 Class-ID: EC000104

ETIM 5.0 Class-Description: Control cable

 

Core identification code

Black with white numbers acc. to VDE 0293-1

 

Specific insulation resistance

> 20 GOhm x cm

 

Conductor stranding

Fine wire according to DIN EN 60228

(VDE 0295), class 5 / IEC 60228 class 5

 

Torsion movement in WTG

TW-0 & TW-1, refer to Appendix T0

 

Minimum bending radius

Occasional flexing: 10 x outer diameter

In power chains: 15 x outer diameter

Fixed installation: 4 x outer diameter

 

Nominal voltage

U0/U: 300/500 V

 

Test voltage

4000 V

 

Protective conductor

G = with GN-YE protective conductor

X = without protective conductor

 

Temperature range

Occasional flexing: -15°C to +70°C

In power chains: -5°C to +70°C

Fixed installation: -40°C to +80°C

Tags: , , , ,